- Medical Equipment
- Electrosurgical Generator
- Surgical Operating Table
- Anesthetic Machine
- Medical Ceiling Supply Unit
- Surgical Light
- Low Temperature Plasma Sterilizer
- Patient Monitor
- Laboratory Equipment
- Biological Safety Cabinet
- Laboratory Centrifuge
- Water Purification System
- CO2/Tri-gas Incubator
- Healthcare Equipment
- Pulse Oximeter
- Portable ECG Monitor
- Fetal Doppler Monitor
- Body Fat Analyzer
- Massager
E6 Multi-Parameter Monitor
Applications
Our E6 Multi-Parameter Monitor offers a variety of applications. It can be used to measure and monitor parameters of SpO2, NIBP, Pulse, TEMP, ECG and RESP. Optional mainstream, sidestream EtCO2 and 1 or 2-Channel IBP monitoring functions are also available.
Features
1. The E6 Multi-Parameter Monitor uses a 15" color TFT display. Up to 9 curves can be simultaneously displayed.
2. It has accessories for all adult, neonatal and pediatric patients.
3. Visual and audible alarms with individual alarm setting are available.
4. The multi-parameter monitor allows storage of up to 1000 groups of NIBP data.
5. Maximum 480 hours trend graphs enable all parameters and trends to be listed.
6. The patient monitor can be networked with PC-1000 PRO central monitoring system.
7. Compact and lightweight, it can be wall mounted or mounted with rolling stand.
ECG | Heart rate display range | 15bpm ~ 350bpm | |
Heart rate display accuracy | ± 1% or ± 2bpm, whichever is greater | ||
Sweeping speed | 12.5mm /s, 25mm/s, 50mm/s | ||
Sensitivity selection | ×1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV | ||
CMRR | ≥ 89dB | ||
RESP | Measuring range | 0rpm~120rpm | |
Accuracy | ±5% or ±2 rpm | ||
Alarm limits setting range | 0rpm~120rpm | ||
TEMP | Measuring range | 25.0℃ ~45.0℃ | |
Measuring accuracy | ±0.2℃ | ||
Responding time | ≤150s | ||
NIBP | Measuring method | Oscillometric Technique | |
Measuring range | 0 mmHg~300mmHg | ||
Accuracy | Maximal mean difference | ±5 mmHg | |
Maximal standard deviation | 8 mmHg | ||
Measurement range | Adult | SYS 40 ~ 255 mmHg | |
MAP 20 ~ 215 mmHg | |||
DIA 10 ~ 195 mmHg | |||
Pediatric patient | SYS 40 ~ 200 mmHg | ||
MAP 20 ~ 165 mmHg | |||
DIA 10 ~ 150 mmHg | |||
Neonate | SYS 40 ~ 135 mmHg | ||
MAP 20 ~ 110 mmHg | |||
DIA 10 ~ 95 mmHg | |||
SpO2 | Measuring range | 35%~100% | |
Low perfusion capability | 0.4%~5% | ||
Accuracy | Not greater than 3% for SpO2 range from 70% to 100% | ||
PR | Measuring range | 30bpm~240bpm | |
Measuring accuracy | ±2bpm or ±2%, whichever is greater |
As a professional multi-parameter monitor manufacturer and supplier in China, it provides a wide array of products that includes anesthetic machine, electrosurgical generator, biological safety cabinet, portable ECG monitor, and much more.